(Question Details) Specific Performance:Broken coal is one of the most common failures of the coal feeder. The coal feeder is the lifeline of the boiler. Its noLearn more>>
-
(Details on the problem) Specific Performance:J valve inlet static pressure fluctuations led to J valve back feed discontinuous, and bed pressure, bed temperatuLearn more>>
-
(Question Details) Specific Performance:(1) There are blasting sounds in the furnace, and the furnace chamber is under positive pressure. There is smoke emittedLearn more>>
-
(Details on the problem) Specific Performance:Slagging pipe blocks during operation of circulating fluidized bed boiler. Answer:cause of failure:(1) The internaLearn more>>
-
(Question Details) Specific Performance:(1) The bed temperature has risen sharply.(2) The oxygen level drops even to zero.(3) The current of the primary blowerLearn more>>
-
(Question Details) Specific Performance:The pipe of superheater bursts in circulating fluidized bed boiler operation.The bed pressure indicator fluctuates littlLearn more>>
-
1. The bed temperature rises sharply.2. Oxygen levels go down and sometimes drop to zero.3. The electric current of primary air fan is less and wind pressure ofLearn more>>
-
1. Primary air fan: after being heated by the air pre-heater, primary air enters into the wind chamber, then into the furnace through wind caps through the airLearn more>>